Room 1604-1, Building F05, Phase III, Software Park, Jimei District, Xiamen,Fujian, China     admin@yumisteel.com      +86-592-6095031

Sandwich Panel Fire Performance

Views: 0     Author: Site Editor     Publish Time: 2026-11-04      Origin: Site

21.jpg

What Are Sandwich Panels and Why Fire Ratings Matter

Sandwich panels are building boards made of two metal skins glued to an insulating core. They go up fast and insulate well, which is why they are common in warehouses, factories, and cold stores. But because the core can be foam (PIR, PUR, EPS) or mineral wool, fire behaviour varies enormously, and getting the rating wrong can mean failed inspections, insurance problems, or genuine danger.

The biggest mistake people make is treating "fire rating" as one number. In reality, there are two separate questions you need to answer.

22.jpg

Question 1: How Does the Panel Behave in a Fire? (Reaction to Fire)

This is about the material itself. Does it catch easily, does it spread flames, does it give off thick smoke or burning drips?

In Europe, panels are graded on a scale from A1 (best, non combustible) to F (worst). Two extra letters tell you about smoke (s1 means little smoke, s3 means lots) and burning droplets (d0 means none, d2 means lots).

Mineral wool panels can achieve A2 s1, d0, essentially non combustible, the safest choice.

PIR foam panels typically achieve B s1, d0. They will burn, but only in a very limited way, with low smoke and no flaming droplets.

EPS panels without enhanced protection rate much lower and are unsuitable for many regulated buildings.

In North America, similar information comes from ASTM E84 tests (flame spread and smoke numbers) and NFPA 285 for exterior walls. Insurers often ask for FM Approvals, which can be tougher than the building code itself.

Question 2: How Long Does the Panel Hold Back a Fire? (Fire Resistance)

This is about the whole wall or roof, specifically how long it keeps flames and heat on one side. Ratings are given in minutes: 30, 60, 90, or 120.

The letters tell you what was tested:

E means no flames or hot gas get through.

I means the far side stays cool enough.

R means the panel keeps carrying its load.

So EI 60 means the assembly held back fire and heat for 60 minutes. REI 120 means it also stayed structural for two hours.

Important: this rating belongs to the tested build up, not the panel alone. Change the thickness, the span, the fixings, or how joints are sealed, and the rating may no longer apply. Always ask the manufacturer for the certificate covering your exact construction.

23.jpg

The Two Ratings at a Glance

Reaction to Fire

Fire Resistance

Asks

Will it make the fire worse?

How long will it contain a fire?

Looks like

B s1, d0 / A2 s1, d0

EI 30 / EI 60 / REI 120

Applies to

The core material

The complete assembled system

When choosing a sandwich panel, check both ratings. Pick the reaction to fire class your building code and insurer require (mineral wool for the highest safety, PIR for good performance in many applications), and confirm the fire resistance duration matches your compartmentation and structural needs, backed by a certificate for the exact assembly you are installing.

For more information needed or any inquiry,please feel free to contact Yumisteel team.

Facebook Messenge